Areas of application

Symbol of a little man running out of the burning houseFire protection
Icon ShelfStorage technology

Product features

Icon with crossed-out bacteria/virusesAntimicrobial
Icon with a glass and a forkFood harmless
Icon with inclined plate and glass on topAnti-slip surface
Icon with a crossed-out flameFlame retardant
Icon plate with weight on itLoad-bearing
Icon with 2 cloudsParticularly low emission

Areas of application

PerformBoard Firestop Cfl P4 is the perfect solution for sustainable storage platforms with high fire protection requirements. In addition to the fire protection classification Cfl – s1 in accordance with DIN EN 13501-1, the particleboard, which is coated on both sides with melamine resin, has a special coating on the underside for high fire resistance. Furthermore, the abrasion-resistant surface (AC4) can be designed in slip resistance class R10 or R12, which means that loads from picking carts or pallet trucks are not a problem. The high proportion of carefully processed recycled wood used in the production process emphasises the sustainability of the end product.

Certificates & labels

CE conformity

The CE-marking documents that goods comply with the safety and health requirements of the European Union. Its aim is to guarantee safe, flawless and high-quality goods on all European markets.

FSC-certified

The Forest Stewardship Council (FSC) is a global, not-for-profit organization dedicated to the promotion of responsible forest management worlwide. FSC defines standards based on agreed principles for responsible forest stewardship that are supported by environmental, social and economic stakeholders.

PEFC certified

PEFC is the largest institution for ensuring sustainable forest management through an independent certification system. Wood and wood products with the PEFC seal originate demonstrably from ecologically, economically and socially sustainable forestry.

Product section

Availability

Formats

Length (mm)Width (mm)Thickness (mm)
5,3102,10038

Product features

Product standard

  • EN 14322

Core material

  • PremiumBoard P4: Wood particleboard type P4 in accordance with EN 312, for structural purposes for use in dry conditions.

Reaction to fire

  • Flame retardant
  • Cfl-s1 (EN 13501-1)
  • B-s1,d0 (EN 13501-1)
  • PerformBoard Firestop fulfills the additional specifications 'lowest smoke emission' and 'no burning droplets' and thus the highest building authority requirements for flame retardant building materials according to EN 13501-1.

EC scope

  • EN 13986:2004 +A1:2015
  • Load-bearing boards for use in dry conditions.

Formaldehyde emission class

  • E1 E05

Antimicrobial effect

  • Surface with antimicrobial effect in 24 h for interior fit-out and finishes – Test Methodology JIS Z 2801 / ISO 22196

Product safety

  • This product follows the REACH regulation EC 1907/2006 an article. Following Article 7 it does not need to be registered.
  • The surface is physiologically safe, and approved for direct contact with food acc. to Regulation (EU) No. 10/2011.
  • We manufacture the panels without the use of halogens, heavy metals, preservatives, wood protectors or organic solvents.

Special

  • FSC certification or PEFC certification available on request.

Colour and surface match

  • Decor, structure and core board all influence the final appearance of the end product.
  • Due to the product-specific differences in production technologies, even identical decor/structure/core board combinations can result in slight optical and tactile deviations across different product groups and formats. Such deviations do not constitute a defect.
  • The choice of surface structure in particular has a significant influence on the visual impression, the tactile perception as well as the technical characteristics of the product. Thus, the overall impression of a decor can change almost completely depending on the surface structure. Furthermore, mechanical influences on the product surface can lead to a higher contrast optical perception with dark decors.
  • To ensure that you always achieve the best results with our products and to clarify any deviations in advance, we will be happy to advise you individually.

Product handling

Machines and tools

  • The fire retardant additives and colourants contained in the support can create deposits on tools and therefore reduce their durability.
    The adhesion of glues can be reduced in exceptional cases.
  • Can be worked with carbide (HW) or diamond (DP) tipped tools on conventional woodworking machines.

Edging

  • Thick and thin edges are suitable.
  • EVA and PUR hotmelts are recommended for edge adhesion.

Fitting technology

  • All conventional removable and non-removable fittings for solid wood and wood materials are suitable.

Installation and assembly

  • Sufficient conditioning is required prior to installation and assembly. The premises themselves need to be at the normal climatic conditions in which the material will later be used.
  • Please ensure that the material is processed and fitted correctly and using the best available technology.

Storage, handling and transport

  • On level, full area surfaces (e.g. pallets), protected against moisture, in dry, ventilated rooms. Outdoor storage is not suitable.
  • Please note that incorrect storage, regardless of its duration, may cause irreversible distortion to the sheets.
  • Foreign bodies or impurities in the pallet of sheets can lead to impressions and damage to the surface of the board.
  • Ensure that sufficiently large and sturdy bases, e.g. pallets, are used for the transportation of stacked sheets. The sheets on the pallet must be secured against slipping.
  • Sheets / boards must not be moved against each other, they should be moved individually by hand or with suction equipment.
  • A protective foil must be removed as soon as possible after processing – but at the latest within 6 months after delivery – to ensure residue-free removal of the foil. In addition, foiled boards must not be exposed to direct sunlight (UV radiation).

Health and safety

  • Please wear the appropriate personal protective equipment (PPE) when processing and handling.

Cleaning and care

  • The surface can be cleaned with water and gentle cleaning agents.
  • The use of cleaning products, cloths, sponges with abrasive ingredients, should be avoided.
  • For removal of particularly stubborn stains, industrial cleaners suitable for plastic surfaces can be used. Before use we would recommend testing in a small, hidden area.

Disposal

  • We recommend material or energy recovery in approved plants.

You like to learn more?

Please get in touch with us! We look forward to hearing from you.

Product enquiries and sales department

+49 (0) 91 81 28 48 0