Areas of application

Furniture and interior fitting

Product features

Individually designed
Food harmless
Particularly low emission

Areas of application

The possible applications are virtually limitless: Individual furniture and interior fitting elements, wall fittings and partitions, shopfitting, trade fair stands, boatbuilding, caravans, hotels, spas, medical centres, offices and living spaces. You will find the right, individually tailored product for every requirement.

Certificates

Blue Angel

The Blue Angel has been the federal government's eco-label for 40 years. Independent and credible, it sets demanding standards for environmentally friendly products and services. The Blue Angel is the orientation for sustainable purchasing.

CE conformity

The CE-marking documents that goods comply with the safety and health requirements of the European Union. Its aim is to guarantee safe, flawless and high-quality goods on all European markets.

FSC® quality available

The FSC trademarks on wood and wood products stand for transparency and credibility worldwide. They ensure that people and nature are treated fairly and responsibly and can be found on a constantly growing range of products worldwide.

PEFC™ quality available

PEFC is the largest institution for ensuring and marketing sustainable forest management through an independent certification system. Wood and wood products with the PEFC seal originate demonstrably from ecologically, economically and socially sustainable forestry.

Product section

Formats

Length (mm)Width (mm)Thickness (mm)Textures
2,800 2,100 16 | 18 | 19 | 22 | 25 | 28 | 30 | 32 | 38 AH | HG | MO | MP | NH | SD | SM | VV

Available surface textures

Product features

Product standard

  • Produced acc. to EN 14322

Core material

  • ClassicBoard P2
  • Urea resin-bonded particleboard, Type P2 to EN 312, suitable for non load-bearing purposes in dry areas.

Reaction to fire

  • D-s2,d0 according to EN 13986 dependent on end use (Thickness: ≥9 mm / Gross density: ≥600 kg/m³)

Formaldehyde emission class

  • E1 E05
  • "CARB Phase 2" / "TSCA Title VI" available on request

Product safety

  • This product follows the REACH regulation EC 1907/2006 an article. Following Article 7 it does not need to be registered.
  • The surface is physiologically safe, and approved for direct contact with food acc. to Regulation (EU) No. 10/2011.

Special

  • Maximum motif format per board, incl. overprinting: 2,750 mm x 2,030 mm. Larger motifs can be tiled.
  • Cut to size is not available.
  • Standard delivery without protective film.
  • Colour differences can occur in follow-up production lots.

Product handling

Processing

  • If possible, each motif is produced around the circumference with an overfill of approx. 15 mm and accordingly cutting marks are set.
  • The motif cutting marks are not binding; therefore, each motif format must be checked before cutting to size.
  • Sawing or formatting the boards in a stack is not possible.
  • Assignment of the motifs parallel with the edge of the coreboard is not possible for production reasons.
  • Sufficient conditioning is required prior to installation and assembly. The premises themselves need to be at the normal climatic conditions in which the material will later be used.
  • For an optimum result when cutting to size we recommend the following measures:
    - Use a universal saw blade with chamfer (WZ/FA), e.g. GlossCut sawblade made by Leitz
    - Hollow ground or trapezoidal tooth sawblades with negative tooth angle
    - Optimized height adjustment of the sawblade
    - Use universal scoring unit
    - Use e.g. a pressure bar or pressure strip to prevent vibration of the material
    - Work with lower feed rate than for standard laminates
  • Use a flat, firm surface to saw and drill on.
  • Please note that sharp curring and quiet running tools are indispensable for perfect results.
  • Drillholes must be countersunk. Through holes must be made oversize.
  • Cutouts and inside corners must have a minimum radius of 8 mm to prevent notch stresses and therefore possible subsequent formation of cracks.
  • Please observe our processing recommendations (see Downloads).
  • We recommend carrying out your own tests depending on the respective application and material requirement.

Machines and tools

  • Can be worked with carbide (HW) or diamond (DP) tipped tools on conventional woodworking machines.
  • Keyhole saws, punches and jars are not suitable.

Edging

  • Can be worked with carbide (HW) or diamond (DP) tipped tools on conventional woodworking machines.
  • Keyhole saws, punches and jars are not suitable.
  • Thick and thin edges are suitable.
  • EVA and PUR hotmelts are recommended for edge adhesion.

Fitting technology

  • All conventional removable and non-removable fittings for solid wood and wood materials are suitable.
  • All conventional furniture fittings and standard profile systems are suitable.

Installation and assembly

  • The material is not suitable for areas subject to large fluctuations in temperature and humidity.
  • Make sure that expansion of installed elements is not prevented. Please observe that when panels are combined with other materials their coefficients of expansion may differ.
  • Ensure adequate room for movement of the panel material in the installed condition. Panel joints are to be made with oversize joints and throughholes.
  • Avoid direct exposure to heat and any possible dehydration of the surfaces by light- or heat radiation or by air currents from heating- or air conditioning systems.
  • Please ensure that the material is processed and fitted correctly and using the best available technology.

Storage, handling and transport

  • The material must be stored flat, level and horizontal on clean surfaces at normal climatic conditions (Temperature 18–25 °C, relative humidity 50–65 %).
  • Avoid storage in the direct vicinity of thoroughfare gates, e.g. in the area of loading and unloading zones.
  • Protect from moisture and wet conditions.
  • Avoid direct exposure to heat and any possible dehydration of the surfaces by light- or heat radiation or by air currents from heating- or air conditioning systems.
  • Avoid exposure to direct sunshine or UV rays, especially of products covered in film.
  • Panels must be fully and horizontally stored with edges flush on a flat and clean base covered with plastic foil. Cover the top panel fully with foil and a cover board.
  • These storage conditions must continue to be ensured after removing panels from the stack.
  • Vertical storage is not recommended.
  • Please note that incorrect storage, regardless of its duration, may cause irreversible distortion to the sheets.
  • Foreign bodies or impurities in the pallet of sheets can lead to impressions and damage to the surface of the board.
  • Sheets / boards must not be moved against each other; they should be moved individually by hand or with suction equipment.
  • Ensure that sufficiently large and sturdy bases, e.g. pallets, are used for the transportation of stacked sheets. The sheets on the pallet must be secured against slipping.
  • To protect the high-quality surface Pfleiderer delivers these surface textures with a protective foil. The protective foil must be removed as soon as possible after processing - but at the latest within 6 months after delivery - to ensure residue-free removal of the foil. In addition, foiled boards must not be exposed to direct sunlight (UV radiation).

Health and safety

  • Please wear the appropriate personal protective equipment (PPE) when processing and handling.
  • Provide adequate extraction when splitting/sanding.

Cleaning and care

  • The surface can be cleaned with water and non-aggressive cleaning products. For more detailed information, please refer to our "Duropal HPL & DecoBoard cleaning recommendation".

Disposal

  • Energy recovery in industrial furnaces at temperatures above 700 °C.

You like to learn more?

Please get in touch with us! We are looking forward to hearing from you.

Product enquiries and sales department

+49 (0) 9181 28 - 480